Example 01 - Calculating flow in pipes under gravity

   
Flow under gravity between Three Reservoirs

This is a classic example that is found in most text books. Three reservoirs are each located at different elevations and are joined at a common point by three pipes.

Example 02 - Calculating pressure drop in a pipe

   
Flow from a tank to an outlet point

This demonstrates flow from a tank through a single pipe that has a fixed demand flow at its end point.

Example 03 - Calculate flow rate to three different pipe outlets

   
Flow from a tank to discharge through 3 spray nozzles

In this example the flow discharges to 3 outlet spray points. Each spray nozzle requires a pressure of at least 2.3 psig pressure to produce the correct spray pattern.

Example 04 - Calculate pump head requirement

   
Pumping fluid from a base tank to higher elevation tanks

Fluid is to be transferred from a tank at low level to 3 tanks located at a higher level. A pump is needed as the motive force to provide the energy to move the fluid.

Example 05 - Analyze pipe system for a specified pump head

   
Find pump head required to deliver a specified flow rate

The required flow rate along all paths of the piping system has been specified. The problem is to determine the pump head needed to deliver the total flow demand. A fixed head pump is used to add pressure to the model. The pump is initially specified to add a pressure of 20 ft head of water as a possible solution.

Example 06 - Pump performance curve and operating point

   
Using a fixed speed pump to transfer chemical fluid to two tanks

This pipe system design includes a stainless steel pump that is used to transfer a chemical to two tanks at a set flow rate. The flow to each tank is regulated by a flow control valve, which is set to limit the flow rate. The system includes a special filter which has been modeled by adding a Component to pipe P3.