[ Return to Pipe Flow Expert FAQs ]

How many components with pressure losses can be modeled?

A component can be added to every pipe in the system, thus up to 1000 individual components can be modeled.

These components can be specified either as a fixed loss, or via a pressure loss curve that describes the pressure loss against a range of flow rates going through the component, or via a Kv or Cv value, which describes the flow rate through the component for a 1 bar or 1 psi pressure drop across the component respectively.

Note: Fittings and valves are not classed as components, in that they are modeled via a K factor value, where the pressure drop is calculated from the flow rate via the equation:

Pressure drop in head of fluid = (K * v * v ) / 2g

K = K factor for a particular fitting or valve v = velocity g = acceleration due to gravity

Up to 5 different type of fittings can be added to each pipe and a quantity of each can be specified, hence many thousands of pipe fittings and valves can be modeled.

[ Return to Pipe Flow Expert FAQs ]